I-MEB2NLE-50 C10 1P+N RCBO Residual Current Operated Circuit Breaker
Imininingwane Yomkhiqizo
• Ukuthobela imithetho: IEC61009-1,AS/NZS 61009.1:2015
• Izitifiketi: CE,CB,SEMKO
• Uhlobo (ifomu lamagagasi okuvuza komhlaba okuzwiwe): AC,A
• Inani lezinsika (P): 1+N
• Isilinganiso samanje ku-(A): 6, 10, 16, 20, 25,32,40,50
• Imvamisa elinganisiwe (Hz): 50/60
• I-voltage elinganisiwe i-Ue (VAC): 230
• I-voltage yokushisa elinganisiwe i-Ui (VAC): 500
• Isilinganiso samanje esisele I△n (mA): 30,100, 300
• Isilinganiso somthamo wokuphuka we-acc.to IEC61009 ultimate Icn (kA): 6
• Isilinganiso somthamo wokuphuka sifinyelela ku-IEC60947-2 ultimate IA m (kA): 10
• Umthamo wokuphuka okusele olinganisiwe I△m (kA): 6
• I-voltage yokumelana nomfutho elinganisiwe I-Uimp: 4kV
• Umsebenzi olinganiselwe: Umsebenzi ongaphazanyiswa
• I-voltage yokuhlola i-dielectric ku-ind.freq.imizuzu eyi-1.(kV): 2.5
• Ukumelana kwamanje okukhuphukayo (igagasi 8/20)(A): 3000
• Isici sokukhubeka: B,C:
Isici B (Ngaphakathi): 3-5
Isici C(In): 5-10
• Impilo kagesi (izikhathi): 4000
• Impilo yemishini (izikhathi): 100000
• Izinga lokuvikelwa: IP20, enama-conductor axhunyiwe
• Indawo yokukhweza: Noma yikuphi
• Izingxenye eziphambene zomqhubi:
Iqinile futhi ilahlekile (mm2): 0.75-35
Iboshwe kahle ngesikhindi sokugcina (mm2): 0.75-25
• Amatheminali:
I-torque yokuqinisa i-terminal (Nm): 2.8
• Izinga lokushisa eliphakathi nendawo (oC): -25~+45, umswakama ophezulu ungama-95%
• Izinga lokushisa lesitoreji(oC): -40~+75
• Ukuphakama Okuphezulu (amamitha): 2000
Ijika
Ububanzi bohlaka kanye nokufakwa (mm)
Inothi Lokuxhuma Kukagesi:
1. Ama-RCBO kumele aqinisekiswe ngokuhlolwa njengafakwe kahle ekufakweni
- Uma i-RCBO inamandla, qinisekisa umsebenzi we-RCD we-RCBO okungenani kabili ngokusebenzisa inkinobho yokuhlola noma ngokusebenzisa imishini yokuhlola ekhethekile.
- Kuzo zonke izimo, ukuhlukaniswa kwazo zonke izigxobo ezishintshiwe kuzoqinisekiswa ngemuva kokuthi i-RCBO isebenze ukuxhuma isekethe ekhethiwe
- Ukuhlukaniswa kwazo zonke izigxobo kuzoqinisekiswa ngokuhlolwa kwamandla kagesi noma, ngemva kokususa ukunikezwa, ngokuhlolwa kokuqhubeka kwegxobo ngalinye
2. Qinisekisa ukuthi akukho mandla noma ugesi oxhunyiwe ngesikhathi sokufakwa ukuze ugweme ukushaqeka kukagesi futhi i-terminal ye-N ingaxhunywa kuphela entanjeni engathathi hlangothi
3. Ungaxhumani ucingo olubukhoma nocingo olubukhoma noma ucingo olubukhoma nohlangothi olungathathi hlangothi ngaphansi kwanoma yiziphi izimo ukuze ugweme ukulimala komuntu siqu
4. Sebenzisa i-torque engu-2.0Nm bese uqinisekisa ukuthi izintambo ziqiniswe kahle.
5. Isandla esimanzi siyavinjelwa ngokuqinile ngesikhathi sokufakwa
6. Sicela usebenzise isivikelo sokuvikela ukuvikela izintambo eziveziwe noma i-copper busbar ukuze ugweme ukujikeleza okufushane
Ukususa i-RCBO kusuka ku-DIN rail, ngemuva kokufakwa kwebhasi
Isicelo
I-Residual Current Operated Circuit Breaker (RCBO) iwuchwepheshe futhi isetshenziswa kabanzi ekwakheni, ezindlini, ezisetshenziswa ezimbonini, nasekudluliseni amandla kagesi.
Ucingo: +86 18066376807